We’re excited to announce that part number 500-2 is now available in our ready-to-ship inventory. Part number 500-2 is a Power Supply manufactured by Ametek Programmable Power Inc with FSC 6130 Converters Electrical Nonrotating. Are you interested in a quick and competitive quote for this part? If so, just fill out the short Request for Quote (RFQ) form below to get started.
As you fill out the RFQ form, make sure that you carefully complete all fields, especially the asterisk-marked (*) fields like Need Parts By and Quantity (ea) for the NSN part 500-2. A majority of your quote will be determined by your response to these fields. One of our dedicated sales representatives will get back to you with your quote in 15 minutes or less after receiving your RFQ for 500-2.
ASAP NSN Parts, owned and operated by ASAP Semiconductor, is a leading distributor of Ametek Programmable Power Inc hard-to-find parts for the aerospace, aviation, and defense industries. We’re an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited member of the Aviation Suppliers Association (ASA). With our vast and comprehensive inventory of over 2 billion parts sourced from over 5000 global manufacturers and our many advanced shipping facilities, we can get you the Ametek Programmable Power Inc NSN parts you need at the fastest delivery times in the industry with same-day and next-day delivery.
Is 15 minutes still too long to wait for a quote? If so, you can call us at our toll-free number, +1-714-705-4780, or email us your Bill of Materials (BOM) at sales@asap-nsnparts.us. We’re available and ready to help, 24/7x365. And for an even faster and more convenient purchasing experience, you can download the ASAP Semiconductor App from Google Play or the App Store.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-363-0912 Item PartTypeName: POWER SUPPLY | 6130 | 013630912 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
500-2 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | END ITEM IDENTIFICATION | F110 ACFT/GE100 ENG |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 3RD POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APNX | INPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 1ST POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 1ST POWER OUTPUT AND 9.2 AC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 2ND POWER OUTPUT AND 2.25 AC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 3RD POWER OUTPUT AND 1.1 AC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWGN | OUTPUT PHASE | TWO 1ST POWER OUTPUT |
CWGN | OUTPUT PHASE | TWO 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 2ND POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | CONSIST OF:2 EA MODEL 251B;1 EA 400SR AND 1 EA 990-302-92 CABLE PLUS ASELECTED OSCILLATOR |
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 16.000 INCHES NOMINAL |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 2ND POWER OUTPUT AND 130.0 AC VOLTS MAXIMUM 2ND POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 1ST POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 1ST POWER OUTPUT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 2ND POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 2ND POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | PROGRAMMABLE AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR |
CWGN | OUTPUT PHASE | TWO 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST ALTERNATE OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 1ST POWER OUTPUT AND 32.0 AC VOLTS MAXIMUM 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 3RD POWER OUTPUT AND 260.0 AC VOLTS MAXIMUM 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |