NSNs, or National Stock Numbers, are 13-digit serials that are assigned to items that are bought, stocked, distributed, and sold via the federal supply chain.
Alternative NSN: 5950-00-301-3734 |
Item Name: Transformer Power |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 003013734 |
NCB Code: USA (00) |
Manufacturers: Amnetics Inc , Magnetika Inc , Northrop Grumman Systems Corporation , Wems Electronics |
Part No. | Manufacturer | Item Name | Quantity | RFQ |
---|---|---|---|---|
Part No.: 420P2 | Manufacturer: wems electronics | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: 20A2680-1 | Manufacturer: northrop grumman systems corporation | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: 420P2 | Manufacturer: magnetika inc | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: 20A2680-1 | Manufacturer: wems electronics | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: WE2189 | Manufacturer: magnetika inc | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: 20A2680-1 | Manufacturer: magnetika inc | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: 420P2 | Manufacturer: amnetics inc | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: JB420P2 | Manufacturer: amnetics inc | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: WE2189 | Manufacturer: wems electronics | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: JB420P2 | Manufacturer: magnetika inc | Item Name: transformer power | Quantity:Avl | RFQ |
Part No.: JB420P2 | Manufacturer: wems electronics | Item Name: transformer power | Quantity:Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 2.750 INCHES MAXIMUM2.750 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM SINGLE GROUP AND 0.148 INCHES MINIMUM SINGLE GROUP AND 0.165 INCHES MAXIMUM SINGLE GROUP0.165 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT420.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENTTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENTINTERNALLY SHIELDED SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.630 INCHES MAXIMUM3.630 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.630 INCHES MAXIMUM1.630 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.5 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.1 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 184.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 184.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 216.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY216.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 21.50 AC VOLTS MINIMUM SINGLE COMPONENT 4TH SECONDARY AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
FEAT | SPECIAL FEATURES | 1PRIMARY,7 SECONDARY WINDINGS; ALL CURRENTS ARE SHOWN AS RECTIFIED; SECONDARIES 6 AND 7 ARE RATED THE SAME,0.1 AMP DC AT 16.5 AND 19.5 VOLTS RMS; 5TH SECONDARY IS 0.57 AMPS AT 21.50 AND 24.50 VOLTS RMS1PRIMARY,7 SECONDARY WINDINGS; ALL CURR |
PKWT | UNABLE TO DECODE | UNABLE TO DECODE |
TTQY | TERMINAL TYPE AND QUANTITY | 24 TAB,SOLDER LUG |
The National Stock Number 5950-00-301-3734 is a 13-digit code assigned to specific military parts to streamline product identification process by Defense Logistics Agency (DLA). Each NSN contains various information for ease of identification, such as 5950-00-301-3734 containing the FSC 5950 Coils and Transformers, as well as a unique NIIN 003013734 to identify this exact item for simplified management and procural. |
On our website, we feature top-requested part numbers like 420P2, 20A2680-1, WE2189, JB420P2 and others, which all fall under NSN 5950-00-301-3734. These part numbers are currently available and ready to ship, so be sure to request a quote at your earliest convenience. |
The FSC code assigned to NSN 5950-00-301-3734 is FSC 5950 Coils and Transformers. This can be determined by the first four digits of an item’s NSN. Federal Supply Classification codes, or FSC codes, are utilized to categorize and standardize products and services procured by the U.S. federal government and other entities, promoting simplified trade. |
The item name associated with NSN 5950-00-301-3734 is “Transformer Power.” |
Manufacturer(s) associated with NSN Number 5950-00-301-3734 on our website include The Boeing Company and others listed on our database. While individual part numbers may vary between manufacturers, NSNs always remain the same for distinct items. |
FSG 59 Electrical and Electronic Equipment Components is associated with NSN Number 5950-00-301-3734. FSG stands for Federal Supply Group, a two-digit numeric code used in the Federal Supply Classification (FSC) system for a more broad method of categorizing items as compared to FSCs. |
Don’t forget That You Can Always Get an Instant RFQ Within Fifteen Minutes Or Less. All You Need to Do Is Fill Out the form On Our Home Page, and You Can Get Started today.
Request for Quote